fbpx

蜘蛛車

蜘蛛車 (曲臂式升降台) 以33尺至45尺 為主是電動 , 45尺以上是油渣。

熱門型號 Z45(13.8M) 可升到45尺 蜘蛛車

升降台Catalog 快速指引 : RM04B(3.8M)SWSL0607DCS(4.5M)GS1930(5.7M)GS2032(6.1M)GS2632(7.9M)GS2646(7.9M)GS3246(9.7M)GS4047(11.7M)GTJZ1412(13.9M)KUDO32(3.2M)KUDO46(4.6M)Z30(8.9M)Z33(10M)Z34(10.5M)Z45(13.8M)Z60(18.4M)JCPT0607DCS(3.9M)ENCL045S

蜘蛛車
蜘蛛車
蜘蛛車

網上24小時極速租升降台:一鍵出機;1分鐘內安排;價錢清晰;到機付款。

提交商業登記後完成手續;到機租機易提供升降台表格一、四及五,  師傳到場會教授升降台操作。

1.24小時網上落單(選好型號)

2.提交商業登記

3.24噸尾板車送到現場,收取現金/支票及教機

延伸閱讀:GS1930 鉸剪車 租一星期收費?鋁架工作台 租賃$2800-$6300【 懶人包】鋁架-【月租鋁架價目表】

2分鐘升降台使用操作教學!一睇明哂!日租升降台攻略升降台買賣資訊<按此>

[DataSource.DSx]
This section is used to specify information for a given datasource, including the
datasource name, the type of datasource and whether the datasource is to be opened as
read-only. There should be a section like this for each name in the OpenNames section

.

DSName=datasource file name or Detector name
The datasource name (DSName) should contain the name of the datasource to be
opened when the workspace file is loaded. The name can be either a detector name or
a qualified CAM file name, i.e. DSName=C:\GENIE2K\CAMFILES\Naidemo.cnf.
ROIName=roi file name
The fully qualified name of the ROI file associated with the current datasource.
DSCType= 769(Detector) / 1(NativeSpect file)
Currently there are two types of datasources, a detector or a file. If the datasource is a detector, then type value should be 769. If the datasource is a file, then type value should be 1.
DSServerType=x
DSServerType indicates VDM type, where x =
M – the VDM supports hardware control access.

.

– the VDM supports file access.

B – the VDM supports both hardware control and file access.
DSServerName=\pipe\datasrce
The DSServerName specifies the path to the datasource.
DSReadOnly=1(On) / 0(Off)
This value is the flag to open that datasource as read only or not. A 1 means On (open
as read only) and 0 means Off (open as read/write).
[Display]
This section contains the available Acquisition and Analysis datasource display options. Each key name corresponds to a display option that affects how the datasource
data is viewed. All the key values, except for CompareDS, are On/Off values, 1 for On
and 0 for Off.
ScaleIsAuto=1(On) / 0(Off)
Set ScaleIsAuto=1 to change the display’s vertical full scale (VFS) automatically.
Set ScaleIsAuto=0 to require that the VFS be set manually (page 117).
319
File Formats
ScaleisLinear=1(On) / 0(Off)
Set ScaleIsLinear=1 to define the display’s scale as Linear.
Set ScaleIsLinear=0 to define the display’s scale as Log (page 117).
Expand=1(On) / 0(Off)
Set Expand=1 to change the display mode to expanded.
Set Expand=0 to restore the display mode to normal (page 115).
Compare=1(On) / 0(Off)
Set Compare=1 to turn the compare function On.
Set Compare=0 to turn the compare function Off (page 117).
CompareDS=datasource file name or Detector name
The CompareDS key value should contain the name of the datasource to be used to
compare with the other loaded datasources. The name can be either a detector name or
a fully qualified CAM file name, i.e. CompareDS=C:\GENIE2K\CAMFILES\Naidemo.cnf.
Genie 2000 Font Customization
It’s possible to customize fonts used in selected portions of Genie 2000 by creating an
file named G2KFONTS.INI in the GENIE2K\CTLFILES directory.
• A section is required in the INI file for each font you want to customize.
• Sections that are not being customized are not required in the INI file.
• The valid section names and their uses are listed below.

.

Report window (within the Gamma/Alpha Acquisition and Analysis windows and the
QA Editor window).
[MVC Status Bar]
Status bars within the Gamma/Alpha Acquisition and Analysis windows.
[MVC Status Pages]
Status pages within the Gamma/Alpha Acquisition and Analysis windows.
[MVC Lists]
Owner drawn listbo